The Alcatel OmniPCX Enterprise can be configured to send its SMDR data over a serial (RS232) or an IP connection.
Alcatel OmniPCX Enterprise – Serial connection
Follow the instructions below to configure the SMDR output via a serial connection. These instructions are taken from the Alcatel OmniPCX Enterprise manual:
Using Telnet, connect to the IP address of your Alcatel OmniPCX Enterprise and follow the steps below:
Applications (Enter)
Accounting (Enter)
Review/Modify (Enter)
All Instance (F1)
Real-time ticket Output: select V24 (serial).
Save changes and exit.
Alcatel OmniPCX Enterprise – IP connection
Follow the instructions below to configure the SMDR output via an IP connection. These instructions are taken from the Alcatel OmniPCX Enterprise manual:
Connect to your PBX via telnet and follow the steps below:
Applications (Enter)
Accounting (Enter)
Review/Modify (Enter)
All Instance (F1)
Real-time ticket Output: Set this to ethernet.(Need license).
Save changes and exit
For IP connection default port is 2533